Cable Entries

Cable glands for industrial, EMC, Ex or hygienic applications and cable entry frames with industry specific approvals.

Expertise and other useful information ...

for EMC cable glands you will find here!

Details on our new Euro-Top EMC Ampacity can be found here!

Product selection cable glands

Please select the characteristics that apply to your requirements:

Cable glands - standard
Cable glands - standard EMV
Cable glands - Ex
Cable glands - Ex EMV
Cable glands - plastic
Cable glands - metal
Cable glands with metric thread
Cable glands with PG thread
Cable glands with NPT thread
Cable glands without thread

Your selection resulted in the following hits:

EURO-TOP PA

EURO-TOP PA

Cable gland tested and approved i.a. according to EN 62444 and UL514B.
Material: Polyamide 6
Protection Class: IP66/IP68
Thread: M; PG; NPT

EURO-TOP PA RAIL

EURO-TOP PA RAIL

Cable gland approved according to EN45545-2.
Material: Polyamide 6
Protection Class: IP66/IP68
Thread: M

EURO-TOP HP PA

EURO-TOP HP PA

Cable gland tested and approved i.a. according to EN 62444 and UL514B. High strain-relief.
Material: Polyamide 6
Thread: M

HSK-K-PVDF

HSK-K-PVDF

Cable gland tested and approved i.a. according to EN 62444 and UL514B. Suitable for high temperatures and chemical applications.
Material: PVDF
Protection Class: IP68
Thread: M

EURO-TOP BIEGESCHUTZ PA

EURO-TOP BIEGESCHUTZ PA

Cable gland tested and approved i.a. according to EN 62444 and UL514B. Incl. bending protection.
Material: Polyamide 6
Protection Class: IP68
Thread: M; PG

EURO-TOP EINSTECK-KV

EURO-TOP EINSTECK-KV

Cable gland without entry thread for the mounting of complete assembled component (e.g. cable harness).
Material: Polyamide 6
Protection Class: IP65

EURO-TOP FRONTFIX PA

EURO-TOP FRONTFIX PA

Quick fitting gland mountable in metric clearance hole.
Material: Polyamide 6

Euro-Top MS

Euro-Top MS

Cable gland tested and approved i.a. according to EN 62444 and UL514B.
Material: Nickel Plated Brass
Thread: M; PG; NPT

EURO-TOP MS LF

EURO-TOP MS LF

Cable gland made of lead-free brass without application of exception regulation 6c, Annex III, RoHS.
Material: Nickel Plated Brass (lead-free)
Protection Class: IP66; IP66/IP68/IP69
Thread: M; PG; NPT

EURO-TOP MS RAIL

EURO-TOP MS RAIL

Cable gland approved according to EN45545-2.
Material: Nickel Plated Brass
Protection Class: IP66/IP68
Thread: M

HSK-M-PVDF

HSK-M-PVDF

Cable gland tested and approved i.a. according to EN 62444 and UL514B. Suitable for high temperatures and chemical applications.
Material: Nickel Plated Brass

HSK-M-FLEX

HSK-M-FLEX

Cable gland tested and approved i.a. according to EN 62444 and UL514B. Incl. bending protection.
Material: Nickel Plated Brass
Thread: M

HSK-MZ

HSK-MZ

Cable gland tested and approved i.a. according to EN 62444 and UL514B. Incl. clamping module for additional strain-relief.
Material: Nickel Plated Brass
Thread: M

EURO-TOP ES

EURO-TOP ES

Cable gland tested and approved i.a. according to EN 62444 and UL514B.
Material: Stainless Steel (303)
Thread: M; PG

EURO-TOP CONNECT METAL

EURO-TOP CONNECT METAL

Cap nut screw connection for securing cable with fixed preassembled plugs (e.g. RJ45, USB)
Material: Nickel Plated Brass; Stainless Steel (303)
Thread: M

EURO-TIGHT

EURO-TIGHT

Cable gland with flat and space saving design and without Polyamide clamping cage.
Material: Nickel Plated Brass
Thread: M

EURO-TOP CONNECT PA

EURO-TOP CONNECT PA

Cable gland with slitted sealing insert for cables with ready fixed connectors (e.g. RJ-45, USB, etc.).
Material: Polyamide 6
Thread: M

EURO-TOP FRONTFIX MS

EURO-TOP FRONTFIX MS

Quick fitting gland mountable in metric clearance hole.
Material: Nickel Plated Brass

EURO-TOP EMV AMPACITY

EURO-TOP EMV AMPACITY

EMC cable gland with patented, active contact system. Very easy and fast to assemble, vibration tested and easy disassembling. Espacially for railway applications with optimal derating performance.
Material: Nickel Plated Brass
Thread: M

EURO-TOP EMV AMPACITY LF

EURO-TOP EMV AMPACITY LF

EMC cable gland with patented, active contact system. Very easy and fast to assemble, vibration tested and easy disassembling. Espacially for railway applications with optimal derating performance. Made of lead-free brass without application of exception regulation 6c, Annex III, RoHS.
Material: Nickel Plated Brass
Thread: M

EURO-TOP EMV 4

EURO-TOP EMV 4

EMC cable gland with patented, active contact system. Very easy and fast to assemble, vibration tested and easy disassembling
Material: Nickel Plated Brass
Thread: M

EURO-TOP EMV 4. GEN LF

EURO-TOP EMV 4. GEN LF

EMC cable gland made of lead-free brass without application of exception regulation 6c, Annex III, RoHS. Very easy and fast to assemble, vibration tested and easy disassembling.
Material: Nickel Plated Brass (lead-free)
Protection Class: IP66/IP68/IP69
Thread: M

EURO-TOP EMV 4 RAIL

EURO-TOP EMV 4 RAIL

EMC cable gland with patented, active contact system. Very easy and fast to assemble, vibration tested and easy disassembling. Approved according to EN45545-2.
Material: Nickel Plated Brass
Protection Class: IP66/IP68
Thread: M

EURO-TOP EMV 3

EURO-TOP EMV 3

EMC cable gland with patented, active contact system. Very easy and fast to assemble.
Material: Nickel Plated Brass
Thread: M

EURO-TOP EMV 3. GEN. LF

EURO-TOP EMV 3. GEN. LF

EMC cable gland made of lead-free brass without application of exception regulation 6c, Annex III, RoHS. Very easy and fast to assemble.
Material: Nickel Plated Brass (lead-free)
Thread: M

EURO-TOP EMV 2

EURO-TOP EMV 2

EMC cable gland with patented contact system. Very easy and fast to assemble.
Material: Nickel Plated Brass
Thread: M; PG

HSK-M-EMV

HSK-M-EMV

Easy EMC cable gland. Screening ends in the cable gland (360° contact system).
Material: Nickel Plated Brass
Thread: M

HSK-M-FLEX-EMV

HSK-M-FLEX-EMV

Easy EMC cable gland. Screening ends in the cable gland (360° contact system). Incl. bending protection.
Material: Nickel Plated Brass
Thread: M

HSK-MZ-EMV

HSK-MZ-EMV

Easy EMC cable gland. Screening ends in the cable gland (360° contact system). Incl. clamping moduls for additional strain-relief.
Material: Nickel Plated Brass
Thread: M

EURO-TOP X 4. GEN.

EURO-TOP X 4. GEN.

Ex e cable gland made of plastic with improved impact resistance of 7 Joule.
Material: Polyamide 6
Thread: M

EURO-TOP X 4. GEN. DS

EURO-TOP X 4. GEN. DS

Ex e cable gland made of plastic with improved impact resistance of 7 Joule and double sealing insert.
Material: Polyamide 6
Thread: M

HSK-M-Ex

HSK-M-Ex

Ex e cable gland made of metal.
Material: Nickel Plated Brass
Thread: M

RNC

RNC

Ex e/d conduit gland with female thread at the cap to allow the installation of e.g. a conduit fitting.
Material: Nickel Plated Brass
Thread: M

HSK-M-EMV-Ex

HSK-M-EMV-Ex

Ex e cable gland made for screened cable (EMC). Screening ends in the cable gland (360° contact system).
Material: Nickel Plated Brass
Thread: M

ADE 1F2

ADE 1F2

Ex e/d cable gland for non armoured cable.
Material: Nickel Plated Brass; Stainless Steel (1.4404)
Thread: M; NPT

A2LBF

A2LBF

Ex e/d cable gland for non armoured cable.
Material: Brass
Thread: M; NPT

RN

RN

Ex e/d cable gland for non armoured cable.
Material: Nickel Plated Brass
Thread: M; NPT

E ALPHA X

E ALPHA X

Ex e/d cable gland for non armoured cable.
Material: Nickel Plated Brass; Stainless Steel (1.4404)
Protection Class: IP66/IP68
Thread: M; NPT

ADE4F

ADE4F

Ex e/d cable gland for armoured cable
Material: Nickel Plated Brass; Stainless Steel (1.4404)
Thread: M; NPT

E1WBF

E1WBF

Ex e/d cable gland for armoured cable.
Material: Brass
Thread: M; NPT

RAD

RAD

Ex e/d cable gland for armoured cable.
Material: Nickel Plated Brass
Thread: M; NPT

GAMMA X UNIVERSAL

GAMMA X UNIVERSAL

Ex e/d cable gland for armoured cable.
Material: Nickel Plated Brass; Stainless Steel (1.4404)
Protection Class: IP66/IP68;
Thread: M; NPT

BRM

BRM

Cable entry plate with fixed cable entries. Improved strain-relief due to the special additional sealing plate. „Snap“ assembling possible with wall thickness of 1,5-2,0 mm.
Material: Polyamide 6, 30% Glass Fibre
Protection Class: IP65

BPAS

BPAS

Modular constructed cable frame incl. universal sealings and mounting screws for pre-assembled cables.
Material: Frame - Polyamide 6 (+GF); Plug Elements - Polyamide 6 (+GF); Sealing Insert - Chloroprene
Protection Class: IP66;

 

 

Cable glands for industrial applications

In the field of industrial electrical installation, cable glands are an indispensable aid. In this field, RST from Wallenhorst near Osnabrück has established itself as a specialist in the cable gland segment. As an owner-managed company, we are now active on an international level and have expanded our business to more than 46 countries. We offer our customers a well-assorted product range in the field of cable glands and accessories.

Cable glands with flexible thread selection

Cable glands are an ideal solution for safely inserting cables and wires - with or without shielding - into electronic housings and for protecting electronic components inside these usually highly sealed housings from damage or undesirable external influences such as dust or moisture. For this reason, we offer a wide range of different cable glands. In order to ensure the most stable connection possible between cables or conductors and enclosures, such as those of an electrical control cabinet, you will find cable glands with different thread types in our product selection:

  • Metric thread, EN 60423
  • PG thread, DIN 40430
  • NPT thread, ANSI B1.20.1

The metric thread - also M-thread - according to EN 60423 is the most common and most sold thread in Europe. Cable glands with armoured conduit thread or PG cable glands are still manufactured, but are increasingly being replaced by metric glands. The third variant is the NPT thread, which is widely used on the American market. The NPT thread is characterized by the fact that it is self-sealing and thus the use of additional sealants can be dispensed with.

Important technical data of our cable glands

The following is a brief overview of other technical data of our cable glands:

Clamping ranges:

  • 2 - 77 mm

protection classes:

  • IP 44
  • IP 54
  • IP 55
  • IP 65
  • IP 66
  • IP 67
  • IP 68
  • IP 69

Temperature ranges:

  • -60 degrees to + 200degrees

Cable glands made of different materials

Different materials are used for RST cable glands, depending on the requirements and the application:

  • Cable gland made of polyamide
  • Cable gland made of brass (nickel-plated)
  • Cable gland made of stainless steel

Depending on the purpose and stress, it makes sense to use a cable gland made of plastic or a cable gland made of metal. A cable gland made of brass is preferably used in connection with electromagnetic compatibility.

Cable glands from RST - competence that connects

Our products have the following approvals, among others:

  • UL, VDE, CSA, DNV

and have been tested according to the following standards, among others:

  • EN 62444
  • NEMA 4X (50E)
  • UL 514B
  • CSA C22.2

Due to our many years of experience and expertise in the field of industrial electrical installations, we can offer you individual solutions for your requirements. As an internationally experienced company in the field of cable glands, we offer our business partners a competent and courteous service far beyond the national borders. Our team is always available for your concerns, we look forward to hearing from you!