Cable glands

Cable glands for industrial, EMC, Ex or railroad applications as well as cable entry frames with approvals typical for the industry.

Cable entries - inconspicuous and yet indispensable

In the field of electrical installation, cable entries are an indispensable aid. RST has established itself as a specialist in this field over several decades - and not only in Germany. As an owner-managed company, we are active internationally in 47 countries. Our customers particularly appreciate our broad and well-structured range of electrotechnical and mechanical products for use in the field of cable entry and fastening. In addition to a broad portfolio of products for industrial applications, we offer numerous solutions for use in potentially explosive atmospheres as well as for applications in which the issue of electromagnetic compatibility (EMC) plays a decisive role.

Expertise EMC

 

Highlight: Euro-Top EMC Ampacity

A highlight in terms of perfect derating properties is our EMC cable gland type "Euro-Top EMC Ampacity". It was specially developed to dissipate high electrical fault currents. A highly efficient contact system with the largest possible effective cross-section ensures low-resistance derivation of the current. This is not only interesting for the railroad sector, the wind power sector or for battery and energy storage solutions, but also for many other high-voltage applications.

Euro-Top EMC Ampacity

Please select the characteristics that apply to your requirements:

Product selection
cable glands

Your selection resulted in the following hits:

Cable glands - standard
Cable glands - standard EMV
Cable glands - Ex
Cable glands - Ex EMV
Cable glands - plastic
Cable glands - metal
Cable glands with metric thread
Cable glands with PG thread
Cable glands with NPT thread
Cable glands without thread
EURO-TOP PA

EURO-TOP PA

Cable gland tested and approved i.a. according to EN 62444 and UL514B.
Material: Polyamide 6
Protection Class: IP66/68; IP66 (NPT)
Thread: M; PG; NPT

New
EURO-TOP PA RAIL

EURO-TOP PA RAIL

Cable gland approved according to EN45545-2.
Material: Polyamide 6
Protection Class: IP66/68
Thread: M

EURO-TOP HP PA

EURO-TOP HP PA

Cable gland tested and approved i.a. according to EN 62444 and UL514B. High strain-relief.
Material: Polyamide 6
Protection Class: IP66/68(10 bar)/69K
Thread: M

HSK-K-PVDF

HSK-K-PVDF

Cable gland tested and approved i.a. according to EN 62444 and UL514B. Suitable for high temperatures and chemical applications.
Material: PVDF
Protection Class: IP54
Thread: M

EURO-TOP BIEGESCHUTZ PA

EURO-TOP BIEGESCHUTZ PA

Cable gland tested and approved i.a. according to EN 62444 and UL514B. Incl. bending protection.
Material: Polyamide 6
Protection Class: IP68
Thread: M; PG

EURO-TOP EINSTECK-KV

EURO-TOP EINSTECK-KV

Cable gland without entry thread for the mounting of complete assembled component (e.g. cable harness).
Material: Polyamide 6
Protection Class: IP65

EURO-TOP FRONTFIX PA

EURO-TOP FRONTFIX PA

Quick fitting gland mountable in metric clearance hole.
Material: Polyamide 6
Protection Class: IP66/68

EURO-TOP MS

EURO-TOP MS

Cable gland tested and approved i.a. according to EN 62444 and UL514B.
Material: Nickel Plated Brass
Protection Class: IP66 (NPT); IP66/68/69K* (PG); IP66/68/69
Thread: M; PG; NPT

New
EURO-TOP MS LF

EURO-TOP MS LF

Cable gland made of lead-free brass without application of exception regulation 6c, Annex III, RoHS.
Material: Nickel Plated Brass (lead-free)
Protection Class: IP66 (NPT); IP66/68/69
Thread: M; PG; NPT

New
EURO-TOP MS RAIL

EURO-TOP MS RAIL

Cable gland approved according to EN45545-2.
Material: Nickel Plated Brass
Protection Class: IP66/68
Thread: M

HSK-M-PVDF

HSK-M-PVDF

Cable gland tested and approved i.a. according to EN 62444 and UL514B. Suitable for high temperatures and chemical applications.
Material: Nickel Plated Brass
Protection Class: IP68(10bar)/69K
Thread: M

HSK-M-FLEX

HSK-M-FLEX

Cable gland tested and approved i.a. according to EN 62444 and UL514B. Incl. bending protection.
Material: Nickel Plated Brass
Protection Class: IP68(10bar)/69K
Thread: M

HSK-MZ

HSK-MZ

Cable gland tested and approved i.a. according to EN 62444 and UL514B. Incl. clamping module for additional strain-relief.
Material: Nickel Plated Brass
Protection Class: IP68(10bar)/69K
Thread: M

EURO-TOP ES

EURO-TOP ES

Cable gland tested and approved i.a. according to EN 62444 and UL514B.
Material: Stainless Steel 303 (316L on Request)
Protection Class: IP66/68/69K* (PG); IP66/68/69
Thread: M; PG

EURO-TIGHT

EURO-TIGHT

Cable gland with flat and space saving design and without Polyamide clamping cage.
Material: Nickel Plated Brass
Protection Class: IP68
Thread: M

VariaPro Temp

VariaPro Temp

EMC-Cable Gland for extremely low temperatures as well of very high temperatures.
Material: Nickel Plated Brass

EURO-TOP CONNECT METAL

EURO-TOP CONNECT METAL

Cap nut screw connection for securing cable with fixed preassembled plugs (e.g. RJ45, USB)
Material: Nickel Plated Brass; Stainless Steel 303
Protection Class: IP66/68/69
Thread: M

VariaPro FKM

VariaPro FKM


Material: Nickel Plated Brass

EURO-TOP CONNECT PA

EURO-TOP CONNECT PA

Cable gland with slitted sealing insert for cables with ready fixed connectors (e.g. RJ-45, USB, etc.).
Material: Polyamide 6
Protection Class: IP66/68/69
Thread: M

EURO-TOP FRONTFIX MS

EURO-TOP FRONTFIX MS

Quick fitting gland mountable in metric clearance hole.
Material: Nickel Plated Brass
Protection Class: IP66/68

EURO-TOP EMV AMPACITY

EURO-TOP EMV AMPACITY

EMC cable gland with patented, active contact system. Very easy and fast to assemble, vibration tested and easy disassembling. Espacially for railway applications with optimal derating performance.
Material: Nickel Plated Brass
Protection Class: IP68
Thread: M

New
EURO-TOP EMV AMPACITY LF

EURO-TOP EMV AMPACITY LF

EMC cable gland with patented, active contact system. Very easy and fast to assemble, vibration tested and easy disassembling. Espacially for railway applications with optimal derating performance. Made of lead-free brass without application of exception regulation 6c, Annex III, RoHS.
Material: Nickel Plated Brass
Protection Class: IP68
Thread: M

EURO-TOP EMV 4. GEN

EURO-TOP EMV 4. GEN

EMC cable gland with patented, active contact system. Very easy and fast to assemble, vibration tested and easy disassembling
Material: Nickel Plated Brass
Protection Class: IP66/68/69
Thread: M

New
EURO-TOP EMV 4. GEN LF

EURO-TOP EMV 4. GEN LF

EMC cable gland made of lead-free brass without application of exception regulation 6c, Annex III, RoHS. Very easy and fast to assemble, vibration tested and easy disassembling.
Material: Nickel Plated Brass (lead-free)
Protection Class: IP66/68/69
Thread: M

New
EURO-TOP EMV 4. RAIL

EURO-TOP EMV 4. RAIL

EMC cable gland with patented, active contact system. Very easy and fast to assemble, vibration tested and easy disassembling. Approved according to EN45545-2.
Material: Nickel Plated Brass
Protection Class: IP66/68
Thread: M

EURO-TOP EMV 3. GEN

EURO-TOP EMV 3. GEN

EMC cable gland with patented, active contact system. Very easy and fast to assemble.
Material: Nickel Plated Brass
Protection Class: IP66/68/69
Thread: M

New
EURO-TOP EMV 3. GEN. LF

EURO-TOP EMV 3. GEN. LF

EMC cable gland made of lead-free brass without application of exception regulation 6c, Annex III, RoHS. Very easy and fast to assemble.
Material: Nickel Plated Brass (lead-free)
Protection Class: IP66/68/69
Thread: M

EURO-TOP EMV 2. GEN

EURO-TOP EMV 2. GEN

EMC cable gland with patented contact system. Very easy and fast to assemble.
Material: Nickel Plated Brass
Protection Class: IP66/68/69
Thread: M; PG

HSK-M-EMV

HSK-M-EMV

Easy EMC cable gland. Screening ends in the cable gland (360° contact system).
Material: Nickel Plated Brass
Protection Class: IP68/69K
Thread: M

HSK-M-FLEX-EMV

HSK-M-FLEX-EMV

Easy EMC cable gland. Screening ends in the cable gland (360° contact system). Incl. bending protection.
Material: Nickel Plated Brass
Protection Class: IP68/69K
Thread: M

HSK-MZ-EMV

HSK-MZ-EMV

Easy EMC cable gland. Screening ends in the cable gland (360° contact system). Incl. clamping moduls for additional strain-relief.
Material: Nickel Plated Brass
Protection Class: IP68/69K
Thread: M

EURO-TOP X 4. GEN.

EURO-TOP X 4. GEN.

Ex e cable gland made of plastic with improved impact resistance of 7 Joule.
Material: Polyamide 6
Protection Class: IP66/68
Thread: M

EURO-TOP X 4. GEN. DS

EURO-TOP X 4. GEN. DS

Ex e cable gland made of plastic with improved impact resistance of 7 Joule and double sealing insert.
Material: Polyamide 6
Protection Class: IP66/68
Thread: M

HSK-M-Ex

HSK-M-Ex

Ex e cable gland made of metal.
Material: Nickel Plated Brass
Protection Class: IP68/69K
Thread: M

HSK-M-EMV-Ex

HSK-M-EMV-Ex

Ex e cable gland made for screened cable (EMC). Screening ends in the cable gland (360° contact system).
Material: Nickel Plated Brass
Protection Class: IP68/69K
Thread: M

ADE 1F2

ADE 1F2

Ex e/d cable gland for non armoured cable.
Material: Nickel Plated Brass; Stainless Steel 1.4404
Protection Class: IP66/68*
Thread: M; NPT

A2LBF

A2LBF

Ex e/d cable gland for non armoured cable.
Material: Brass
Protection Class: IP66/68; IP66/68*
Thread: M; NPT

RN

RN

Ex e/d cable gland for non armoured cable.
Material: Nickel Plated Brass
Protection Class: IP66/68*
Thread: M; NPT

E ALPHA X

E ALPHA X

Ex e/d cable gland for non armoured cable.
Material: Nickel Plated Brass; Stainless Steel 1.4404
Protection Class: IP66/68
Thread: M; NPT

ADE4F

ADE4F

Ex e/d cable gland for armoured cable
Material: Nickel Plated Brass; Stainless Steel 1.4404
Protection Class: IP66/68*
Thread: M; NPT

E1WBF

E1WBF

Ex e/d cable gland for armoured cable.
Material: Brass
Protection Class: IP66/68*
Thread: M; NPT

RAD

RAD

Ex e/d cable gland for armoured cable.
Material: Nickel Plated Brass
Protection Class: IP66/68*
Thread: M; NPT

GAMMA X UNIVERSAL

GAMMA X UNIVERSAL

Ex e/d cable gland for armoured cable.
Material: Nickel Plated Brass; Stainless Steel 1.4404
Protection Class: IP66/68
Thread: M; NPT

BRM

BRM

Cable entry plate with fixed cable entries. Improved strain-relief due to the special additional sealing plate. „Snap“ assembling possible with wall thickness of 1,5-2,0 mm.
Material: Polyamide 6, 30% Glass Fibre
Protection Class: IP65

BPAS

BPAS

Modular constructed cable frame incl. universal sealings and mounting screws for pre-assembled cables.
Material: Frame - Polyamide 6 (+GF); Plug Elements - Polyamide 6 (+GF); Sealing Insert - Chloroprene
Protection Class: IP66

 

 

Cable glands for industrial applications

In the field of industrial electrical installation, cable glands are an indispensable aid. In this field, RST from Wallenhorst near Osnabrück has established itself as a specialist in the cable gland segment: Standard and EMC, for explosion-proof areas, made of metal or plastic, with metric, PG thread or NPT thread as well as without thread. As an owner-managed company, we are now active on an international level and have expanded our business to more than 45 countries. We offer our customers a well-assorted product range in the field of cable glands and accessories.

Expertise and further useful information on EMC cable glands can be found here:

Expertise EMC Cable Glands

Cable glands with flexible thread selection

Cable glands with flexible thread selection

Cable glands are an ideal solution for safely inserting cables and wires - with or without shielding - into electronic housings and for protecting electronic components inside these usually highly sealed housings from damage or undesirable external influences such as dust or moisture. For this reason, we offer a wide range of different cable glands. In order to ensure the most stable connection possible between cables or conductors and enclosures, such as those of an electrical control cabinet, you will find cable glands with different thread types in our product selection:

  • Metric thread, EN 60423
  • PG thread, DIN 40430
  • NPT thread, ANSI B1.20.1

The metric thread - also M-thread - according to EN 60423 is the most common and most sold thread in Europe. Cable glands with armoured conduit thread or PG cable glands are still manufactured, but are increasingly being replaced by metric glands. The third variant is the NPT thread, which is widely used on the American market. The NPT thread is characterized by the fact that it is self-sealing and thus the use of additional sealants can be dispensed with.

Important technical data of our cable glands

Important technical data of our cable glands

The following is a brief overview of other technical data of our cable glands:

Clamping ranges:

  • 2 - 77 mm

protection classes:

  • IP 44
  • IP 54
  • IP 55
  • IP 65
  • IP 66
  • IP 67
  • IP 68
  • IP 69

Temperature ranges:

  • -60 degrees to + 200degrees
Cable glands made of different materials

Cable glands made of different materials

Different materials are used for RST cable glands, depending on the requirements and the application:

  • Cable gland made of polyamide
  • Cable gland made of brass (nickel-plated)
  • Cable gland made of stainless steel

Depending on the purpose and stress, it makes sense to use a cable gland made of plastic or a cable gland made of metal. A cable gland made of brass is preferably used in connection with electromagnetic compatibility.

Cable glands from RST - competence that connects

Cable glands from RST - competence that connects

Our products have the following approvals, among others:

  • UL, VDE, CSA, DNV

and have been tested according to the following standards, among others:

  • EN 62444
  • NEMA 4X (50E)
  • UL 514B
  • CSA C22.2

Due to our many years of experience and expertise in the field of industrial electrical installations, we can offer you individual solutions for your requirements. As an internationally experienced company in the field of cable glands, we offer our business partners a competent and courteous service far beyond the national borders. Our team is always available for your concerns, we look forward to hearing from you!